Telemetry:servo Sensor - FUTABA T12K Instruction Manual

Digital propotional r/c system. t-fhss air-2.4ghz
Hide thumbs Also See for T12K:
Table of Contents

Advertisement

TELEMETRY : Servo sensor
The SBS-01S can monitor and display the
in-flight current, operating angle, and internal
temperature of up to two S.BUS2 servos.
If you forget to connect the servo wiring during
fuselage assembly, or the servo was disconnected,
an alarm can be activated at the transmitter.
TO Receiver
S.BUS2 Port
When it's servo 2, select #2.
● Select [CURR.#1] in the TELEMETRY screen and access the
setup screen shown below by pushing the RTN button.
● Select the function name
and return to the Linkage
menu by pushing the RTN
button or pushing the
HOME/EXIT button.
RETURN
● ↑ An upward arrow
indicates the alarm
will sound when the
c u r r e n t r e a c h e s
above your set value.
● ↓ A downward arrow
indicates the alarm
will sound when the
current reaches below
your set value.
●Current alarm setting range 0 ~ 9.9A
(↑THRESHOLD > ↓THRESHOLD)
*Alarm when the current has decreased.
Alert setting when servo #1 current increases
1. Set "↑ALERT" on the <CURR.#1> screen to
ACT. Move the cursor to INH and push the RTN
button.
2. Select the ACT mode by scrolling the Push dial.
3. Push the RTN button. (To terminate the input
and return to the original state, push the S1
button.)
4. The current at which an alarm is generated
can be set by selecting the current display next
to "↑ THRESHOLD" and pushing the RTN button.
This generates an alarm when the current
increases.
5. Adjust the rate by scrolling the Push dial.
*When the RTN button is pushed for one second, the rate is
reset to the initial value.
6. Push the RTN button. (To terminate the input
and return to the original state, push the S1
button.)
116
<Functions of Linkage Menu>
[Current]
SBS-01S
●Push the S1 button to advance to the next page.
Displaying data from the S.BUS servo
*SBS-01S must be installed in the aircraft.
*It cannot be used in S-FHSS mode
● Displays the maximum/minimum data
after the transmitter is turned on.
●Displays the current data
<Push Dial>
●Current alarm setting range
(↑THRESHOLD > ↓THRESHOLD)
*Alarm when the current has increased.
If the following types are selected, the
transmitter will vibrate during the warning.
TYPE 1
TYPE 2
TYPE 3
TYPE 4
Alert setting when servo #1 current decreases
1. Select page 2 by pushing S1 from the
<CURR.#1> screen and set " ↓ ALERT" to ACT.
2. Select the ACT mode by scrolling the Push
dial.
3. Push the RTN button. (To terminate the input
and return to the original state, push the S1
button.)
4.The current at which an alarm is generated
can be set by selecting the numerical display
next to " ↓ THRESHOLD" and pushing the RTN
button. This sounds an alarm when the current
decreases.
5. Adjust the rate by scrolling the Push dial.
*When the RTN button is pushed for one second, the rate is
reset to the initial value.
6. Push the RTN button. (To terminate the input
and return to the original state, push the S1
button.)
Servo #1
Servo #2
S.BUS2 servo
Scrolling
● Moving cursor
● Selecting mode
● Adjusting value
● To input data mode
● Data is entered
● To next page
0.1 ~ 10A
"Vibes" type

Advertisement

Table of Contents
loading

Table of Contents