Setting method
●Gyro type selection
Move the cursor to the gyro type selection
item and push the RTN button to switch to
the data input mode. Select the gyro type
by scrolling the Push dial.
[GY]: When a Futaba GY gyro is used
[NORM]: When a non-Futaba GY gyro is
used.
Push the RTN button to change the gyro type
and return to the cursor mode.
*When a Futaba GY gyro is used and [GY] type is selected,
the sensitivity set value is directly read in both the AVCS
and NORM modes.
●Operation mode selection (GY gyro)
Move the cursor to the operation mode
selection item and push the RTN button to
switch to the data input mode. Select the
operation mode by scrolling the Push dial.
[AVCS]: AVCS mode
[NORM]: Normal mode
Push the RTN button to change the operation
mode and return to the cursor mode.
●Sensitivity setting
Move the cursor to the rate item and push
the RTN button to switch to the data input
mode.
Adjust the sensitivity by scrolling the Push dial.
Initial value: 80%
Adjustment range: 0~100%
*When the RTN button is pushed for one second, the
sensitivity is reset to the initial value.)
Push the RTN button to return to the cursor
mode.
●Fine tuning VR settings
Move the cursor to the [--] item and push the
RTN button to access the selection screen.
Select the control.
*For a description of the switch selection method, see the
description at the back of this manual.
Move the cursor to the rate item and push
the RTN button to switch to the data input
mode.
Adjust the trim rate by scrolling the Push dial.
Initial value: 0%
Adjustment range: -20~+20%
*When the RTN button is pushed for one second, the
sensitivity is reset to the initial value.)
Push the RTN button to return to the cursor
mode.
182
<Functions of Model Menu (Helicopter Functions)>
<EXAMPLE>Rudder gyro gain is changed with
a switch (SF) irrespective of condition.
Generally, gain is interlocked with condition
and changes a rate.
H o w t o c h a n g e t w o r a t e s i n t h e s a m e
condition here.
1. Select [GYRO] at the Model menu and
access the setup screen shown below by
pushing the RTN button.
2. Move the cursor to the [COND] item and
push the RTN button to access the selection
screen. Select the [SW]. Push the RTN button
to return to the cursor mode.
3. # number shows the present switch state. In
the state of # 1 a cursor is moved to [--] and
RTN is pushed.
4. [SF] is chosen by [H/W SELECT] and then a
top is turned ON.
5. [TYPE GY] and [RATE] of a state of "#1=SF
top" are set up.
SF : Top = #1
6. It is a setup of "#2". Move the cursor to
the [#1] item and push the RTN button to
access the selection screen. Select the [#2].
Push the RTN button to return to the cursor
mode.
The number