Maintaining The Mx104 Air Filter - Juniper MX104 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX104:
Table of Contents

Advertisement

MX104 3D Universal Edge Router Hardware Guide
Meaning
Related
Documentation

Maintaining the MX104 Air Filter

Purpose
Action
Related
Documentation
190
PIC 0/0 Channel 6
PIC 0/0 Channel 7
PIC 0/0 Channel 8
PIC 1/0 Channel 0
PIC 1/0 Channel 1
PIC 1/0 Channel 2
PIC 1/2 Channel 0
PIC 1/2 Channel 1
PIC 1/2 Channel 2
Fans
Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
is displayed in the
Check
Status
the
Status
column if the fan is functioning normally.
For further description of the output from the command, see the show chassis environment
command summary in the
MX104 Cooling System and Airflow Overview on page 19
Replacing an MX104 Fan Tray on page 146
For optimum cooling, verify the condition of the air filter.
Regularly inspect the air filter. A dirty air filter restricts airflow in the unit, producing a
negative effect on the ventilation of the chassis. The filter degrades over time. You
must replace the filter every 6 months.
CAUTION:
Always keep the air filter in place while the router is operating.
Because the fans are very powerful, they could pull small bits of wire or
other materials into the router through the unfiltered air intake. This could
damage the router components.
The shelf life of polyurethane filter varies from two years to five years depending on
the storage conditions. Store in a cool, dry, and dark environment. Wrap the media in
plastic and store in an environment with relative humidity between 40%- 80% and
temperature between 40°F (4° C) to 90°F (32° C). Note that if the material flakes,
or becomes brittle when rubbed or deformed, it is no longer usable.
Replacing an MX104 Air Filter on page 143
Routine Maintenance Procedures for the MX104 Router on page 187
OK
29 degrees C / 84 degrees F
OK
28 degrees C / 82 degrees F
OK
44 degrees C / 111 degrees F
OK
45 degrees C / 113 degrees F
OK
30 degrees C / 86 degrees F
OK
31 degrees C / 87 degrees F
OK
42 degrees C / 107 degrees F
OK
29 degrees C / 84 degrees F
OK
30 degrees C / 86 degrees F
Check
OK
Spinning at high speed
OK
Spinning at high speed
OK
Spinning at high speed
OK
Spinning at high speed
column if a fan that is not functioning.
.
CLI Explorer
is displayed in
OK
Copyright © 2017, Juniper Networks, Inc.