Inside Air Temperature Sensor Inspection; Condenser Assembly Removal And Installation; Condenser Assembly Inspection; Desiccant Removal And Installation - Suzuki Liana RH413 Service Manual

Table of Contents

Advertisement

Inside Air Temperature Sensor Inspection

Measure resistance between each connector terminal
with an ohmmeter.
If resistance is incorrect, replace inside air temperature
sensor with new one.
Inside air temperature sensor resistance
1.7 kΩ ± 85 Ω at 25 °C (77 °F)
5.5
Resistance
1.7

Condenser Assembly Removal and Installation

Refer to "Condenser Assembly Removal and
Installation".

Condenser Assembly Inspection

Refer to "Condenser Assembly Inspection".

Desiccant Removal and Installation

Refer to "Desiccant Removal and Installation".
Condenser Cooling Fan Removal and
Installation
Refer to "Condenser Cooling Fan Removal and
Installation".

Condenser Cooling Fan Inspection

Refer to "Condenser Cooling Fan Inspection".
S3RH0A7226043
0
25
32
77
F
Temperature
I3RH0A722025-01
S3RH0A7226022
S3RH0A7226023
S3RH0A7226024
S3RH0A7226025
S3RH0A7226026
Air Conditioning System: Automatic Type 7B-74

A/C Evaporator Removal and Installation

Refer to "A/C Evaporator Removal and Installation".
A/C Evaporator Inspection
Refer to "A/C Evaporator Inspection".
A/C Evaporator Outlet Air Temperature Sensor
Removal and Installation
Refer to "A/C Evaporator Inlet and Outlet Air
Temperature Sensor Removal and Installation".
A/C Evaporator Outlet Air Temperature Sensor
Inspection
Check resistance between terminals for A/C evaporator
outlet air temperature sensor (1).
If measured resistance is out of specification, replace A/
C evaporator outlet air temperature sensor with new
one.
A/C evaporator outlet air temperature sensor
resistance
0 °C (32 °F): 6.4 – 6.9 kΩ
25 °C (77 °F): 1.8 – 2.2 kΩ
S3RH0A7226027
S3RH0A7226028
S3RH0A7226029
S3RH0A7226030
I3RH0A722027-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liana rh416