Extra Fan Operation
1-953-004
ON/OFF Setting
1955
[Fan Control]
Dev Cooling Fan Op Sw
1-955-004
Temp
Paper Exit Cooling Fan Op
1-955-006
Sw Temp
1-955-007 Fusing Fan Op Sw Temp
Ozone Fan Low Speed Op
1-955-009
Sw Temp
Ozone Fan Middle Speed
1-955-010
Op Sw Temp
Ozone Fan High Speed Op
1-955-011
Sw Temp
Ozone Fan Low Noise Op
1-955-012
DUTY
Ozone Fan Low Speed Op
1-955-013
DUTY
Ozone Fan Middle Speed
1-955-014
Op DUTY
Ozone Fan High Speed Op
1-955-015
DUTY
Paper Exit Cooling Fan Op
1-955-016
Start Time A
PSU Cooling Fan Op Start
1-955-017
Time A
1-955-018 Fan Op Sw Temp Thers
*ENG
[0 or 1 / 1 / 1/step]
0: disable
1: enable
*ENG
[0 to 100 / 36 / 0.1deg/step]
*ENG
[0 to 100 / 12 / 0.1deg/step]
*ENG
[0 to 100 / 0 / 0.1deg/step]
*ENG
[0 to 100 / 35 / 0.1deg/step]
*ENG
[0 to 100 / 37 / 0.1deg/step]
*ENG
[0 to 100 / 40 / 0.1deg/step]
*ENG
[0 to 100 / 20 / 1%/step]
*ENG
[0 to 100 / 30 / 1%/step]
*ENG
[0 to 100 / 40 / 1%/step]
*ENG
[0 to 100 / 40 / 1%/step]
*ENG
[0 to 900 / 300 / 1sec/step]
*ENG
[0 to 900 / * / 1sec/step]
*MP C3004/C3504: 300
*MP C4504/C5504/C6004:
*NA: 120, EU: 40, Asia: 40, CN: 40,
TW: 120 , KR: 40
*ENG
[0 to 100 / 2 / 0.1deg/step]
Engine SP Tables-1
219