Technical data

13.9 Display, keyboard and auxiliary power

Torques
Tightening torque for union nut made
of metal/stainless steel
13.9
Display, keyboard and auxiliary power
Display and user interface
Keys
Display
Auxiliary power U
H
Terminal voltage on pressure transmit-
ter
Ripple
Noise
Auxiliary power
Separate supply voltage
Bus voltage
Not
For intrinsically safe operation
Current consumption
Max. basic current
Starting current ≤ basic current
Max. current in event of fault
Error shut-down electronics (FDE)
present
224
4 Nm (3 ft lb)
3 for on-site programming directly at the device
With or without integrated display (optional)
Cover with inspection window (optional)
HART
DC 10.5 V ... 45 V
In the case of intrinsically safe
operation 10.5 V ... 30 V DC
U
≤ 0.2 V (47 ... 125 Hz)
SS
U
≤ 1.2 mV (0.5 ... 10 kHz)
eff
PROFIBUS PA or Foundation Fieldbus
Bus-powered
Not necessary
9 ... 32 V
9 ... 24 V
12.5 mA
Yes
15.5 mA
Yes
SITRANS P DS III/P410 with PROFIBUS PA
Operating Instructions, 02/2016, A5E00053276-08