Siemens SITRANS P DS III Operating Instructions Manual page 198

Digital pressure transmitter
Hide thumbs Also See for SITRANS P DS III:
Table of Contents

Advertisement

Technical data
13.2 SITRANS P DS III input
Absolute pressure input (from the differential pressure series)
Upper measuring limit
Start of scale value
Order the nominal measuring range with the order option Y01 for PROFIBUS PA or FOUNDATION Fieldbus.
1)
Differential pressure and flow rate input
Measured variable
Span (continuously adjustable) or measur-
ing range and max. operating pressure (in
accordance with 97/23/EC Pressure
Equipment Directive)
198
100 % of max. span (for oxygen measurement: max.
100 bar/10 MPa/1450 psi and 60 °C ambient temperature/process tempera-
ture)
Between the measuring limits (fully adjustable)
Differential pressure and flow rate
Span
1)
1 ... 20 mbar
0.1 ... 2 kPa
0.4015 ... 8.031 inH
O
2
1 ... 60 mbar
0.1 ... 6 kPa
0.4015 ... 24.09 inH
O
2
2.5 ... 250 mbar
0.2 ... 25 kPa
1.004 ... 100.4 inH
O
2
6 ... 600 mbar
0.6 ... 60 kPa
2.409 ... 240.9 inH
O
2
16 ... 1600 mbar
1.6 ... 160 kPa
6.424 ... 642.4 inH
O
2
50 ... 5000 mbar
5 ... 500 kPa
20.08 ... 2008 inH
O
2
0.3 ... 30 bar
0.03 ... 3 MPa
4.35 ... 435 psi
2.5 ... 250 mbar
0.25 ... 25 kPa
1.004 ... 100.4 inH
O
2
6 ... 600 mbar
0.6 ... 60 kPa
2.409 ... 240.9 inH
O
2
16 ... 1600 mbar
1.6 ... 160 kPa
6.424 ... 642.4 inH
O
2
Maximum operating pressure MAWP
(PS)
32 bar
3.2 MPa
464 psi
160 bar
16 MPa
2320 psi
160 bar
16 MPa
2320 psi
160 bar
16 MPa
2320 psi
160 bar
16 MPa
2320 psi
160 bar
16 MPa
2320 psi
160 bar
16 MPa
2320 psi
420 bar
42 MPa
6091 psi
420 bar
42 MPa
6091 psi
420 bar
42 MPa
6091 psi
SITRANS P DS III/P410 with PROFIBUS PA