Siemens SITRANS P DS III Operating Instructions Manual page 220

Digital pressure transmitter
Hide thumbs Also See for SITRANS P DS III:
Table of Contents

Advertisement

Technical data
13.8 Construction
Construction for gauge pressure, with flush mounted diaphragm
Electrical connection
Degree of protection for Han and
M12 connectors
Han 8D is identical to Han 8U.
1)
Construction of pressure transmitter with PMC connection
Weight
Material
Wetted parts materials
Gasket (standard)
O-ring (minibolt)
Seal diaphragm
Non-wetted parts materials
Electronics housing
Mounting bracket
Measuring cell filling
Process connection
Standard
Minibolt
220
Cable inlet using the following cable glands:
Pg 13.5
M20x1.5
½-14 NPT
Han 7D/Han 8D plug
1)
M12 connector
IP65
Approx. 1.5 kg (3.3 lb) for aluminum enclosure
PTFE flat gasket
FPM (Viton)
FFPM or NBR (optional)
Hastelloy C276, mat. No. 2.4819
Non-copper aluminum die casting GD-AlSi 12 or stainless steel precision cast-
ing, mat. no. 1.4408
Standard: Powder coating with polyurethane
Option: 2 coats: Coat 1: epoxy-based; coat 2: polyurethane
Stainless steel nameplate
Steel or stainless steel
Silicone oil
Inert liquid
Flush mounted
1
/
''
1
2
PMC Standard design
Flush mounted
1''
PMC Minibolt design
SITRANS P DS III/P410 with PROFIBUS PA
Operating Instructions, 02/2016, A5E00053276-08