Description
3.7 Principle of operation
3.7.2

Operation of the electronics

Description
Image 3-4
Function
● The inlet pressure is converted into an electrical signal by the sensor
● This signal is amplified by the measuring amplifier
converter
● The digital signal is analyzed in a microcontroller
and thermal characteristics.
● The signal is available at an electrically isolated PA interface
28
Measuring cell sensor
Measuring amplifier
Analog-to-digital converter
Microcontroller
Electrical isolation
Each with an EEPROM in the measuring cell
and in the electronics
PROFIBUS PA interface
Principle of operation of the electronics with PA communication
.
Buttons (local operation)
Display
Power supply
DP/PA coupler or DP/PA link
Bus master
p
Input variable
e
and digitized in an analog-to-digital
and corrected with regard to linearity
on the PROFIBUS PA.
SITRANS P DS III/P410 with PROFIBUS PA
Operating Instructions, 02/2016, A5E00053276-08
.