Rated conditions for absolute pressure (from the differential pressure series), differential pressure and flow rate
Installation conditions
Installation instruction
•
Ambient conditions
Ambient temperature
•
Note
Measuring cell with silicone oil
filling
Measuring cell
•
30 bar (435 psi)
Measuring cell with inert liquid
Display
Storage temperature
Climate class
•
Condensation
Degree of protection in accord-
•
ance with EN 60529
Degree of protection in accord-
•
ance with NEMA 250
Electromagnetic compatibility
•
Interference emission and inter-
ference immunity
Process medium conditions
Process temperature
•
Measuring cell with silicone oil
filling
Measuring cell
•
30 bar (435 psi)
Measuring cell with inert liquid
Measuring cell
•
30 bar (435 psi)
In conjunction with dust explo-
sion protection
Rated conditions for level
Installation conditions
Installation instruction
•
Ambient conditions
Ambient temperature
•
SITRANS P DS III/P410 with PROFIBUS PA
Operating Instructions, 02/2016, A5E00053276-08
any
Observe the temperature class in hazardous areas.
-40 ... +85 °C (-40 ... +185 °F)
-20 ... +85 °C (-4 ... +185 °F)
•
For flow: -20 ... +85 °C (-4 ... +185 °F)
•
-20 ... +85 °C (-4 ... +185 °F)
-30 ... +85 °C (-22 ... +185 °F)
-50 ... +85 °C (-58 ... +185 °F)
Permitted
IP66, IP68
NEMA 4X
In accordance with EN 61326 and NAMUR NE 21
-40 ... +100 °C (-40 ... +212 °F)
-20 ... +85 °C (-4 ... +185 °F)
-20 ... +100 °C (-4 ... +212 °F)
-20 ... +85 °C (-4 ... +185 °F)
-20 ... +60°C (-4 ... +140°F)
specified through the flange
Technical data
13.7 Operating conditions
217