Sitrans P Ds Iii Input - Siemens SITRANS P DS III Operating Instructions Manual

Digital pressure transmitter
Hide thumbs Also See for SITRANS P DS III:
Table of Contents

Advertisement

Technical data

13.2 SITRANS P DS III input

13.2
SITRANS P DS III input
Gauge pressure input
Measured variable
Span continuously adjustable) or measuring
range, max. operating pressure (in accord-
ance with 97/23/EC Pressure Equipment
Directive) and max. test pressure (in ac-
cordance with DIN 16086) (for oxygen
measurement, max. 100 bar and 60 °C
ambient temperature/process temperature
)
Low measuring limit
2)
Measuring cell with silicone oil filling
Measuring cell with inert liquid
Upper measuring limit
Start of scale value
Order the nominal measuring range with the order option Y01 for PROFIBUS PA or FOUNDATION Fieldbus.
1)
With 250mbar/25 kPa/3.6 psi measuring cells, the lower measuring limit is 750 mbar a/75 kPa a/10.8 psi a. The measur-
2)
ing cell is vacuum-tight down to 30 mbar a/3 kPa a/0.44 psi a.
194
Gauge pressure
Span
1)
8.3 ... 250 mbar
0.83 ... 25 kPa
0.12 ... 3.6 psi
0.01 ... 1 bar
1 ... 100 kPa
0.15 ... 14.5 psi
0.04 ... 4 bar
4 ... 400 kPa
0.58 ... 58 psi
0.16 ... 16 bar
16 ... 1600 kPa
2.3 ... 232 psi
0.63 ... 63 bar
63 ... 6300 kPa
9.1 ... 914 psi
1.6 ... 160 bar
0.16 ... 16 MPa
23 ... 2321 psi
4 ... 400 bar
0.4 ... 40 MPa
58 ... 5802 psi
7 ... 700 bar
0.7 ... 70 MPa
102 ... 10153 psi
30 mbar a/3 kPa a/0.44 psi a
30 mbar a/3 kPa a/0.44 psi a
100 % of max. span (for oxygen measurement: max.
100 bar/10 MPa/1450 psi and 60 °C ambient temperature/process tempera-
ture)
Between the measuring limits (fully adjustable)
Maximum operating
pressure MAWP (PS)
4 bar
400 kPa
58 psi
4 bar
400 kPa
58 psi
7 bar
0.7 MPa
102 psi
21 bar
2.1 MPa
305 psi
67 bar
6.7 MPa
972 psi
167 bar
16.7 MPa
2422 psi
400 bar
40 MPa
5802 psi
800 bar
80 MPa
11603 psi
SITRANS P DS III/P410 with PROFIBUS PA
Operating Instructions, 02/2016, A5E00053276-08
Maximum test pressure
6 bar
0.6 MPa
87 psi
6 bar
0.6 MPa
87 psi
10 bar
1 MPa
145 psi
32 bar
3.2 MPa
464 psi
100 bar
10 MPa
1450 psi
250 bar
2.5 MPa
3626 psi
600 bar
60 MPa
8702 psi
800 bar
80 MPa
11603 psi

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans p410

Table of Contents