Bit Switch Programming - Ricoh J-P3 Service Manual

Table of Contents

Advertisement

20 February 2004
1105
[ToneCtlSave]
Saves the print gamma (adjusted with the Gamma Adj.) as the new Current Setting.
Before the machine stores the new "current setting", it moves the data stored as the
"current setting" to the "previous setting" memory-storage location.
1106
[Toner Limit]
Adjusts the maximum toner amount for image development.
1106 001 TonerLimitPhot
1106 002 TonerLimitText
1107
[FactoryTestPrt]
Prints the test page to check the color balance before transportation (600 x 600 2
bit). DFU

5.2.2 BIT SWITCH PROGRAMMING

Do not change the bit switches unless you are told to do this by the manufacturer.
1. Start the SP mode. The "Service" menu is shown.
2. Press the enter key two times.
3. To select a bit switch, press the up arrow key or the down arrow key.
4. Push the enter key.
5. Set the value with these keys:
• [!] ["]:
Moves the cursor to one of the adjacent bits.
• [Escape]: Goes out of the program without saving changes.
• [Enter]:
Goes out of the program and saves changes.
NOTE: The digit at the left [A] is bit 7 and the digit at
the right [B] is bit 0.
6. Push the escape key one or more times until the
menu "Service" is shown.
7. Select "End" and push the enter key.
CONTROLLER SERVICE MODE
*CTL [100 to 400 / 260 / 1 %/step]
*CTL [100 to 400 / 190 / 1 %/step]
5-7