Displays the value given by the following formula:
(Current revolution ÷ Target revolution) × 100, where "Current revolution" is the current value for
the counter of the part, and "Target revolution" is the values of SP7-803-17 through 27. This
shows how much of the unit's expected lifetime has been used up.
The R% counter is based on rotations, not prints. If the number of rotations reaches the limit, the
machine enters the end condition for that unit. If the print count lifetime is reached first, the
machine also enters the end condition, even though the R% counter is still less than 100%.
Oil supply unit: When the R% counter reaches 100%, it enters the near-end condition, not the
end condition. The end condition occurs some number of rotations after this (not adjustable).
NOTE: The machine internally adjusts or compensates as necessary, depending on conditions of
machine usage. Due to this, at the oil supply unit near-end condition, the R% counter of the oil
supply unit can be 100%, lower than 100%, or higher than 100%.
7803 038 R(%): PCU [K]
7803 039 R(%): PCU [Y]
7803 040 R(%): PCU [M]
7803 041 R(%): PCU [C]
7803 042 R(%): Dev [K]
7803 043 R(%): Dev [Y]
7803 044 R(%): Dev [M]
7803 045 R(%): Dev [C]
7803 046 R(%): Oil Spply
7803 047 R(%): Fusing
7803 048 S: Trans Cln
7803 049 R: Trans Cln
7804
[PM Counter Reset]
(Unit, [Color])
Dev.: Development Unit, PF: Paper Feed Rollers, Transfer: Transfer Unit
7804 001 Paper
7804 002 PCU [K]
7804 003 PCU [Y]
7804 004 PCU [M]
7804 005 PCU [C]
7804 006 Dev. [K]
7804 007 Dev. [Y]
7804 008 Dev. [M]
7804 009 Dev. [C]
7804 010 Oil Supply
7804 011 PF By-pass
7804 012 PF Tray 1
7804 013 PF Tray 2
7804 014 PF Tray 3
7804 015 PF Tray 4
7804 016 Fusing
7804 017 Transfer
7804 018 Trans Cln
7804 050 All
7807
[SC/Jam Clear] SC/Jam Counter Clear
Clears the counters related to SC codes and paper jams.
7808
[Counter Clear] (☛ 5.3.2)
Clears all counters.
*BCU
*BCU
*BCU
*BCU
*BCU
*BCU
*BCU
*BCU
*BCU
*BCU
*BCU
*BCU
Clears the PM counter.
Press the Enter key after the machine asks
"Execute?".
When a unit is replaced, the machine
automatically detects that the new unit is installed.
Then, the current PM counter value is
automatically moved to the b PM Counter -
Previous (SP7-906-1 to 25) and is reset to "0".
NOTE: The LCT is counted as the 3rd feed
station.