ENGINE SERVICE MODE
3906
[PC SelfChk] Process Control Self-checks
3906 001
Job End
Specifies the execution timing of the job end process control self-check.
The job end process control self-check is automatically done after a job is completed
when 200 prints have been made since the last self-check.
The counter for the job end process control self-check resets when one of the
following process control self-checks is done.
• Initial
• Interval: Interrupt
• Non-use Time
• During Toner End
When K prints are made, the number of prints is calculated with the K coefficient in
SP3-906-5.
3906 002
Interrupt
Specifies the execution timing of the interrupt process control self-check.
The interrupt process control self-check is automatically done if the number of prints
in the job exceeds the number set in this SP mode. When the print job is completed,
the counter is reset, even if the interrupt self check did not occur.
When K prints are made, the number of prints is calculated with the K coefficient in
SP3-906-5.
3906 003
Non-use Time 1
Specifies the executing timing of the non-use time process control self-check.
The non-use time process control self-check is automatically done after the number
of prints set with this SP mode have been made and no prints have been made for
the time set with SP mode 3-906-4 since the last print job.
If the conditions are met, the self-check will be done after the print job is completed.
The counter is reset when the initial process control self-checks is done or when a
print is made.
3906 004
Non-use Time 2
Specifies the executing timing of the non-use time process control self-check.
3906 005
K Coefficient
Sets the coefficient to calculate the counter value for black-and-white prints.
With the default setting (100), counters used for process control count up by 1 when
1 black-and-white print has been made.
3910
[Vmin Display] Vmin Display ([Color])
3910 001
[K]
Displays the current Vmin value for K
3910 002
[Color]
Displays the lowest current Vmin value for the colors (CMY).
3911
[Vt Display Cur] Vt Current Display ([Color])
3911 001
[K]
3911 002
[Y]
3911 003
[M]
3911 004
[C]
3912
[Vt Display Ave] Vt Average Display ([Color])
3912 001
[K]
3912 002
[Y]
3912 003
[M]
3912 004
[C]
*BCU [0 to 999 / 200 / 1 print/step]
*BCU [0 to 999 / 0 / 1 print/step]
*BCU [0 to 999 / 0 / 1 print/step]
0: Disable
*BCU [0 to 2550 / 480 / 10 minutes/step]
0: Disable
*BCU [0 to 1.00 / 1.00 / 0.01/step] DFU
*BCU [0 to 2.00 / 0 / 0.01/step]
*BCU [0 to 2.00 / 0 / 0.01/step]
*BCU
Displays the current Vt value.
[0.0 to 5.0 / - / 0.1V/step]
*BCU
*BCU
*BCU
*BCU
Displays the average Vt value.
[0.0 to 5.0 / - / 0.1V/step]
*BCU
*BCU
*BCU
5-30