ENGINE SERVICE MODE
1008
[Drum STM Speed] Drum STM Speed Adjustment
Adjusts the drum speed. This SP does not change the transfer belt speed.
1008 001 [CL]: L
1008 002 [CL]: M
1008 003 [Bk]: M
1008 004 [Bk]: M
1008 005 OHP
1008 006 MUSIC
1008 007 [Bk]: L: TH
1104
[Fusing Cont.] Fusing Control
1104 001
Control Method
Selects the fusing control method.
0: ON/OFF Control
1: Phase Control
NOTE: This mode can be used only for N. America models.
1104 025 Process Speed
1105
[Fusing Temp.] Fusing Temperature
(Heating or Pressure roller: Paper Type, [Color], Simplex/Duplex, Process Speed)
Paper Type -> N: Normal, OHP. TH: Thick, SP: Special
Some settings of fusing temperature depend on the destination (US or
Europe/Asia).
US: Setting for US, EU: Setting for Europe/Asia
1105 001
H: Ready
Sets the heating roller temperature for the printing ready condition.
After the main switch has been turned on, the machine enters the print ready
condition when the heating roller temperature reaches the temperature specified in
this SP mode.
When the machine is in the recovery mode from the energy saver or auto off mode,
the machine becomes ready when both heating and pressure roller temperatures
reach the specified temperature.
Ready temperature = (Target temperature specified in SP1-104-25 or 105-3 to 28) –
Temperature specified in this SP mode.
1105 002
P: Ready
Sets the pressure roller temperature for the printing ready condition.
Ready temperature = (Target temperature specified in SP1-104-25 or 105-3 to 28) –
Temperature specified in this SP mode
The following SPs set the target temperatures of the heating and pressure rollers. (NA: North
America, EU: Europe and Asia, L: Low speed [62.5 mm/s], M: Middle speed [162 mm/s], H: High
speed (Not used in this machine)
1105 004 H: N [K] S: M
1105 006 H: N [K] D: M
1105 008 H: N[FC] S: L
*BCU [0 to 10/ 7 / 1 /step] DFU
*BCU [0 to 10/ 6 / 1 /step] DFU
*BCU [0 to 10/ 5 / 1 /step] DFU
*BCU [0 to 10/ 5 / 1 /step] DFU
*BCU [0 to 10/ 4 / 1 /step] DFU
*BCU [0 to 10/ 2 / 1 /step] DFU
*BCU [0 to 10/ 5 / 1 /step] DFU
*BCU [0 or 1 / 0 / -] Alphanumeric
*BCU Selects the default target fusing temperature.
When you turn on the main power switch, the
fusing temperature is set to this temperature. The
target fusing temperature depends on the process
speed. Select one of the following processes:
• Color: Middle Speed
• Color: Low Speed
• Black and White: High Speed
• Black and White: Middle Speed
• OHP, Thick Paper
*BCU [10 to 100 / 10 / 1
*BCU [10 to 100 / 10 / 1
*BCU [100 to 190 / 185 / 5°C/step]
*BCU [100 to 190 / 180 / 5°C/step]
*BCU [100 to 190 / 145 / 5°C/step]
5-10
20 February 2004
o
C/step]
o
C/step]