[Save Debug Log]
5857 001
On/Off
Enables or disables the debug log saving function.
5857 002
Target
Sets the storage location for the debug log.
5857 005
Save to HDD
Sets the key number of the debug log.
5857 006
Save to SD
Sets the key number of the debug log.
5857 009
HDD to SD (4MB)
Copies the most recent 4 MB of the debug log from the hard disk to the SD card.
5857 010
HDD to SD (Any)
Sets the key number of the debug log copied from the hard disk to the SD card.
5857 011
Erase HDD Log
Deletes the debug log from the hard disk.
5857 012
Erase SD Log
Deletes the debug log from the SD card.
5857 013
Free Space on SD
Shows the free space on the SD card.
5857 014
SD to SD (4MB)
Copies the most recent 4 MB of the debug log from an SD card to a different SD
card.
5857 015
SD to SD (Any)
Sets the key number of the debug log copied from an SD card to a different SD
card.
5857 016 Make HDD Log File
5857 017 Make SD Log File
5858
[Debug Save When]
5858 001
Engine SC Error
Collects debug logs when an engine-related SC code occurs.
5858 002
System SC Error
Collects debug logs when a controller-related SC code occurs.
5858 003
Any SC Error
Sets the SC code whose logs are collected.
5858 004
Jam
Collects debug logs when a paper jam occurs.
5859
[Log Save Key No.]
5859 001 Key 1
5859 002 Key 2
*CTL [0 to 1 / 0 / 1/step]
0: Disabled, 1: Enabled
*CTL [2 to 3 / 2 / 1/step]
2: Hard disk, 3: SD card
*CTL
*CTL
*CTL
*CTL
*CTL
*CTL
*CTL
*CTL
*CTL
*CTL
Makes a log file on the HDD to save debug logs.
To save debug logs, the controller makes a log file
*CTL
first, then writes data in the file. This procedure
can use much time. The user can switch off the
main power switch before the log is written in the
file. To prevent this possible problem, you can
prepare a log file in advance. If you do this, the
controller uses less time to save logs because the
log file is prepared.
*CTL [0 to 1 / 0 / 1/step]
0: Collected, 1: Not collected
*CTL [0 to 1 / 0 / 1/step]
0: Collected, 1: Not collected
*CTL [00000 to 65535 / 0 / 1/step]
*CTL [0 to 1 / 0 / 1/step]
0: Collected, 1: Not collected
*CTL [0000000 to 9999999 / 0 / 1/step]
Sets the key number of a specific event (☛ NOTE)
whose logs are saved in the specified storage (☛
5-39