Ricoh J-P3 Service Manual page 81

Table of Contents

Advertisement

20 February 2004
SC No.
Item
SC 480
Waste toner
The waste toner bottle does
bottle full
not push the waste toner
sensor feeler.
SC 481
Waste toner
The waste toner vibrator does
vibrator error
not operate.
SC 543
Heating roller
The detected fusing
fusing lamp
temperature stays at 220°C or
overheat
more for five seconds.
SC 555
Pressure roller
When the fusing unit is not
fusing lamp
running in the Ready condition,
consecutive full
the pressure roller fusing lamp
keeps ON with full power for
power
150 seconds continuously
(North America) or 190
seconds continuously
(Europe).
Definition
Possible Cause
• The waste toner
bottle is full.
• The waste toner
bottle is not correctly
set.
• Loose connection
• Defective motor
• Defective PSU
• Defective BCU
• Pressure roller
thermistor out of
position
Related
SCs
1. Replace the waste toner bottle.
2. Check that the waste toner bottle is
correctly lifted and that the bottle
pushes the waste toner sensor feeler.
3. Close the front cover. Wait 10
seconds. Turn the main switch off and
on.
1. Turn the main switch off and on.
2. Check the connection.
3. Replace the motor.
1. Replace the PSU.
2. Replace the BCU.
1. Replace the fusing unit.
4-7
Troubleshooting Procedure
SC TABLE