4.
Close the Scanner Unit.
5.
Tighten the screw (x1) finally after making sure that there
is no gap between the Scanner Unit and the printer.
Check the gap
Figure 4-12. Installing the Scanner Unit (3)
Make sure to insert the terminal of the grounding wire to the
fixing rib of the Frame. (See
For the routing of the FFCs, see
(p.196).
When installing the Cable Cover, secure it with a new Harness
Cover Clamp. (See
After removing/replacing the Scanner Unit, make the specified
A D J U S T M E N T
R E Q U I R E D
adjustments. (See
Chapter 5
DISASSEMBLY/ASSEMBLY
Screw (Final tightening)
Fig.
4-7.)
"4.4 Routing FFC/cables"
Fig.
4-4.)
"ADJUSTMENT".)
4.2.3.3 Hinge
Parts/Components need to be removed in advance:
ADF Unit (Artisan 810/835/837/PX810FW/TX810FW/PX820FWD/TX820FWD/
PX830FWD only)/Scanner Unit
Removal procedure
1.
Remove the screw (x1) that secures the Hinge and remove the Hinge.
Hinge
Disassembly Procedures
C.B.P. 3x10 (6±1Kgfcm) (Artisan 810/835/837/PX810FW/TX810FW/
PX820FWD/TX820FWD/PX830FWD)
C.B.P. 3x12 (black) (6±1Kgfcm) (Artisan 710/725/730/PX710W/TX710W/
PX720WD/TX720WD/PX730WD/TX730WD)
Figure 4-13. Removing the Hinge
Revision G
113