September 2016
1-4 Platform Em ergency Stop Button
1-4

Platform Emergency Stop Button

How to Remove the Platform
Controls Emergency Stop Button
1
Push in the red Emergency Stop button to the
off position at both the ground and platform
controls.
2
Disconnect the platform controls from the
control cable at the platform.
3
Remove the fasteners securing the platform
control box to the platform control bracket.
4
Remove the fasteners securing the bottom
cover to the platform control box. Open the
control box.
Part No. 1272217
5
6
7
8
GS-30 • GS-32 • GS-46 • GS-47
Service and Repair Manual
Platform Controls
Disconnect the white wires from the
Emergency Stop base.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Component damage hazard.
Electrostatic discharge (ESD)
can damage printed circuit board
components. Maintain firm
contact with a metal part of the
machine that is grounded at all
times when handling printed
circuit boards OR use a
grounded wrist strap.
Carefully remove the Emergency Stop base
from the Emergency Stop button.
Carefully remove the retaining ring from the
Emergency Stop button.
Carefully remove the Emergency Stop button
from the platform control box.