Type "FXXX" Faults, continued
DTC
Message on
Number
GCON LCD
F012:
F012:SENSORFAULT
GS-3232
LEVEL PITCH:BAT+
F013:
F013:SENSORFAULT
LEVEL PITCH:BAT-
GS-3232
F014:
F014:SENSORFAULT
LEVEL ROLL:BAT+
GS-3232
F015:SENSORFAULT
F015:
GS-3232
LEVEL ROLL:BAT-
F016:SENSORFAULT
F016:
GS-3232
LF RIGGER:BAT+
F017:
F017:SENSORFAULT
GS-3232
LF RIGGER:BAT-
F018:
F018:SENSORFAULT
GS-3232
RF RIGGER:BAT+
F019:
F019:SENSORFAULT
GS-3232
RF RIGGER:BAT-
F020:
F020:SENSORFAULT
GS-3232
LR RIGGER:BAT+
F021:
F021:SENSORFAULT
LR RIGGER:BAT-
GS-3232
F022:
F022:SENSORFAULT
RR RIGGER:BAT+
GS-3232
Part No. 1272217
Description
Short circuit of the Level Pitch Sensor circuit
to battery positive.
Short circuit of the Level Pitch Sensor circuit
to battery negative.
Short circuit of the Level Roll Sensor circuit to
battery positive.
Short circuit of the Level Roll Sensor circuit to
battery negative.
Short circuit of the Left Front Outrigger
Sensor circuit to battery positive.
Short circuit of the Left Front Outrigger
Sensor circuit to battery negative.
Short circuit of the Right Front Outrigger
Sensor circuit to battery positive.
Short circuit of the Right Front Outrigger
Sensor circuit to battery negative.
Short circuit of the Left Rear Outrigger
Sensor circuit to battery positive.
Short circuit of the Left Rear Outrigger
Sensor circuit to battery negative.
Short circuit of the Right Rear Outrigger
Sensor circuit to battery positive.
GS-30 • GS-32 • GS-46 • GS-47
Service and Repair Manual
Type "FXXX" Faults
Possible Causes
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the left front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the left front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the right front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the right front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the left rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the left rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the right rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Failure Mode
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
Left front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
Left front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
Right front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
Right front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
Left rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
Left rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
Right rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
175

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents