Genie GS-1530 Service And Repair Manual page 45

Scissor lifts
Hide thumbs Also See for GS-1530:
Table of Contents

Advertisement

September 2016
11 Select the Load Flash File button to verify the
file is a .gff file.
Result: The following screen will be displayed.
12 Select the Reprogram Device(s) button to
start the ECM software update.
Result: The following screen will be displayed
after the software update is complete.
Note: Do not turn off power while the ECM is being
reprogrammed.
13 Select the Run Application button to exit the
software update mode.
14 Push in the red Emergency Stop button and
disconnect the CAT5 cable from the GCON.
Part No. 1272217
15 Secure the diagnostic port cover using the
Note: Machines equipped with AGM batteries will
need to select the AGM battery type using the
GCON set parameters screen. Refer to the
Machine Setup procedure in the Service and
Repair manual that is appropriate for your machine.
16 Perform a function test. Refer to the
17 Return the machine to service.
GS-30 • GS-32 • GS-46 • GS-47
Service and Repair Manual
Ground Controls
retaining fasteners removed in step 5. Do not
over tighten.
Tip over hazard. Updating the
SmartLink software may have
impacted the machines default
drive speeds. Tipping over the
machine will result in death or
serious injury.
Perform drive speed test. Refer
to the Maintenance Manual that
is appropriate for your machine.
Operator's Manual on your machine.
29