Genie GS-1530 Service And Repair Manual page 64

Scissor lifts
Hide thumbs Also See for GS-1530:
Table of Contents

Advertisement

Service and Repair Manual
Ground Controls
Outrigger Level Sensor - GS-3232
Models
(from serial number GS3211A to GS3215A-141898)
(from serial number GS3212C-10000)
Tip-over hazard. Failure to install
the level sensor as instructed will
compromise machine stability
and cause the machine to tip
over, resulting in death or
serious injury. Do not install the
level sensor other than specified
in this procedure.
1
Move the machine to an area that has a firm,
level surface and is free of obstructions.
2
Turn the key switch to the off position and
push in the red Emergency Stop button to the
off position at both the ground and platform
controls.
3
Open the access door at the battery side of
the machine.
4
Tag and disconnect the outrigger level sensor
wire harness from the outrigger level sensor.
5
Remove the outrigger level sensor retaining
fasteners and remove the outrigger level
sensor from the machine.
48
6
7
8
9
10 Close the access door at the battery side of
11 Calibrate the outrigger level sensor. Refer to
GS-30 • GS-32 • GS-46 • GS-47
Place the new outrigger level sensor onto the
outrigger level sensor base with the flat side of
the outrigger level sensor closest to the
battery side access door. Refer to the
illustration below.
1 outrigger level sensor (GS-3232)
Secure the outrigger level sensor onto the
base with the retaining fasteners removed in
step 5.
Adjust the outrigger level sensor retaining
fasteners until the bubble at the top of the level
sensor is centered in the circles.
Connect the outrigger level sensor wire
harness to the new outrigger level sensor.
the machine.
Repair Procedure, How to Calibrate the
Outrigger System.
September 2016
Part No. 1272217