Genie GS-1530 Service And Repair Manual page 192

Scissor lifts
Hide thumbs Also See for GS-1530:
Table of Contents

Advertisement

Service and Repair Manual
Type "FXXX" Faults
Type "FXXX" Faults, continued
DTC
Message on
Number
GCON LCD
F023:
F023:SENSORFAULT
GS-3232
RR RIGGER:BAT-
F034:
GS30,
F034:SENSORFAULT
GS32,
OVLD:PLAT HEIGHT
GS46 &
GS47
F035:
GS30,
F035:SENSORFAULT
GS32,
OVLD RANGE:LOW
GS46 &
GS47
F036:
GS30,
F036:SENSORFAULT
GS32,
OVLD RANGE:HI
GS46 &
GS47
F072:
F072:SENSORFAULT
GS-2646AV
FUNCTION CUT B+
F073:
F073:SENSORFAULT
DECK SENSOR B+
GS-2646AV
F129:
GS30,
F129:TILT SENSOR FAULT
GS32,
GS46 &
GS47
176
Description
Short circuit of the Right Rear Outrigger
Sensor circuit to battery negative.
Height Sensor settings are not calibrated
correctly.
Height Sensor setting is lower than calibrated
stowed height.
Height Sensor setting is higher than
calibrated maximum height.
Function Cutout sensor B+ fault.
Power Deck sensor B+ fault.
UTS mismatch fault. Two accelerometers
inside UTS mismatch.(universal tilt sensor)
GS-30 • GS-32 • GS-46 • GS-47
Possible Causes
• Short circuit in the right rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Height sensor needs calibration for stowed
height and maximum height settings.
• GCON or PCON ECM.
• Height sensor not calibrated for stowed height
correctly.
• GCON or PCON ECM.
• Height sensor not calibrated for maximum height
correctly.
• GCON or PCON ECM.
• Faulty extension deck limit switch.
• Faulty gate proximity switch.
• GCON ECM.
• Short circuit in deck sensor input circuit.
• GCON ECM.
• Faulty UTS.
September 2016
Failure Mode
Right rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.