Emergency Stop - Genie S-105 Operator's Manual

Hide thumbs Also See for S-105:
Table of Contents

Advertisement

Operator's Manual
Operating Instructions
Starting the Engine
1 At the ground controls, turn the key switch to
the desired position.
2 Be sure both ground and platform control red
Emergency Stop buttons are pulled out to the
on position.
Deutz models
1 Diesel models with glow plug button: Push the
glow plug button.
Diesel models with automatic glow plugs:
Amber light will be on when glow plugs are on.
2 Move the engine start toggle switch
to either side. The engine start
switch can be moved at any time
while the glow plugs are on. If the
engine fails to start or dies, the
restart delay will disable the start
switch for 3 seconds.
Perkins models
1 Move the glow plug switch to either side and
hold.
2 Move the engine start toggle switch to either
side. If the engine fails to start or dies, the
restart delay will disable the start switch for 3
seconds.
If the engine fails to start after 15 seconds of
cranking, determine the cause and repair any
malfunction. Wait 60 seconds before trying to start
again.
In cold conditions, 20°F / -6°C and below, warm
the engine for 5 minutes before operating to
prevent hydraulic system damage.
In extreme cold conditions, 0°F / -18°C and below,
machines should be equipped with optional cold
start kits. Attempting to start the engine when
temperatures are below 0°F / -18°C may require
the use of a booster battery.
46

Emergency Stop

Push in either the ground or platform red
Emergency Stop button to the off position to stop
all functions and turn the engine off.
Repair any function that operates when the red
Emergency Stop button is pushed in.
Selecting and operating the ground controls
will override the platform red Emergency Stop
button.
Emergency Controls
Use emergency power if the primary power source
(engine) fails.
1 Turn the key switch to ground or platform
control.
2 Pull out the red Emergency Stop button to the
on position.
3 Press down the foot switch when operating the
emergency controls from the platform.
4 Simultaneously hold the
emergency power button and
activate the desired function.
The drive function will not
operate with emergency power.