Emergency Stop - Genie Z-60/34 Operator's Manual

Hide thumbs Also See for Z-60/34:
Table of Contents

Advertisement

Fourth Edition · First Printing
Starting the Engine
1 At the ground controls, turn the key switch to
the desired position.
2 Be sure both the ground and platform control
red Emergency Stop buttons are pulled out to
the on position.
3 Gasoline/LPG models: Choose fuel by moving
the fuel select switch to the desired position.
4 Move the engine start toggle
switch to either side. If the engine
fails to start or dies, the restart
delay will disable the start switch
for 3 seconds.
If the engine fails to start after 15 seconds of
cranking, determine the cause and repair any
malfunction. Wait 60 seconds before trying to start
again.
All models: In extreme cold conditions, 20°F
(-6°C) and below, warm the engine for 5 minutes to
prevent hydraulic system damage.

Emergency Stop

Push in either the ground or platform red
Emergency Stop button to the off position to stop
all functions and turn the engine off.
Repair any function that operates when the red
Emergency Stop button is pushed in.
Selecting and operating the ground controls will
override the platform red Emergency Stop button.
Part No. 82315
Auxiliary Controls
Use auxiliary power only if the primary power
source (engine) fails.
1 Turn the key switch to ground or platform
control.
2 Pull out the red Emergency Stop button to the
on position.
3 Press down the foot switch when operating the
auxiliary controls from the platform.
4 Simultaneously hold the auxiliary power switch
on and activate the desired function.
The drive function will not operate with auxiliary
power.
Operation from Ground
1 Turn the key switch to ground control.
2 Pull out the red Emergency Stop button to
the on position.
3 Start the engine.
To Position Platform
1 Hold the function enable switch to either side.
2 Move the appropriate toggle switch according to
the markings on the control panel.
Drive and steer functions are not available from the
ground controls.
Machines equipped with Platform Level Control
Disable Function: The platform level toggle switch
will not operate when the primary boom is raised or
extended or the secondary boom is raised past the
drive speed limit switches.
Genie Z-60/34
Operator's Manual
OPERATING INSTRUCTIONS
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents