Ricoh D065 Service Manual page 599

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Service Program Mode Tables
Starts the standard white density adjustment for the CIS. Place 5 sheets of A3
on the exposure glass, then press Execute. A message is displayed to indicate
the success or failure of the adjustment. DFU
GB Target R DFU
4706*
001 [0 to 1023 / 689 / 1 digit]
GB Target G DFU
4707*
001 [0 to 1023 / 684 / 1 digit]
GB Target B DFU
4708*
001 [0 to 1023 / 669 / 1 digit]
4709*
GB Chart Level R
Displays the GB chart level for Red signal:
001
[0 to 1023 / - / 1 digit]
4710*
GB Chart Level G
Displays the GB chart level for Green signal:
001
[0 to 1023 / - / 1 digit]
4711*
GB Chart Level B
Displays the GB chart level for Blue signal:
001
[0 to 1023 / - / 1 digit]
GB Adj Value R DFU
4712*
GB Adj Value G DFU
4713*
GB Adj Value B DFU
4714*
001 [-512 to 512 / 0 / -]
D062/D063/D065/D066
4-66
SM Appendix

Advertisement

Table of Contents
loading

Table of Contents