Ricoh D065 Service Manual page 789

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Input/Output Check
011 Skew Correction Sensor
012 Interval Sensor
013 Registration Sensor
014 Exit Sensor
015 Feed Cover Sensor
016 DF Position Sensor
018 Pick-up Roller HP Sensor
020 APS Start Sensor
021 Bottom Plate HP Sensor
022 Bottom Plate Posirion Sensor
4.2.4 ADF OUTPUT CHECK: SP6008
1.
Open SP mode SP6008.
2.
Select the SP number that corresponds to the component you wish to check. (Refer to
the table below.)
3.
Press On then press Off to test the selected item. You cannot exit and close this
display until you click Off to switch off the output check currently executing.
ADF Output Check
6008
Turns on the ADF electrical components individually for testing.
001 Feed Motor: Forward
002 Feed Motor: Reverse
003 Transport Motor: Forward
004 Exit Motor: Forward
008 Stamp Solenoid
D062/D063/D065/D066
No paper
No paper
No paper
No paper
Open
Open
Not HP
Not Start
Not HP
Not Correct
Position
4-256
Paper detected
Paper detected
Paper detected
Paper detected
Close
Close
HP
Start
HP
Correct Position
SM Appendix