Service Program Mode Tables
Push [Execute] to execute the process control cycle manually.
Note: This SP executes only if SP3901 is enabled.
2963
Installation Mode
Use the keyboard display to enter the lot number of the developer. (The lot
number is embossed on the top edge of the developer pack.)
Press "Execute" to initialize the developer and force toner supply to the toner
hopper at machine installation.
Important: After you replace developer in a machine that has been already
installed, do not use SP2963 to initialize the developer. Use SP2801 (TD Sensor
Initial Setting) to initialize the TD sensor.
001 Execute
002 Developer Lot Number Input
2964*
Transfer Cleaning Blade Forming
001 Pattern Interval Setting
Selects the interval for application of a strip of toner across drum and transfer
belt to prevent the drum cleaning blade and belt cleaning blade from sticking
and bending against the drum or belt.
[0 to 200/0/1] DFU
If set to zero, then no pattern is created.
002 Pattern Light Amount Setting
Adjusts the intensity of light that is used to create the blade protection pattern.
[0 to 4/2/1] DFU
003 Transfer Current On/Off Setting
Determines whether transfer current is switched on or off while the blade
protection pattern is created. DFU
Sets Off, toner is applied to the entire cleaning area and drum cleaning blade.
[0 to 1/1]
0: Off
D062/D063/D065/D066