Ricoh D065 Service Manual page 376

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Display
E24 Power Off/On
30
No Valid Data E30
Reboot After Card
31
Insert E31 Module
ID Card No. xx/xx
Reboot After Card
32
Insert E32 Module
ID Card No. xx/xx
33
No Valid Data E33
34
No Valid Data E34
35
No Valid Data E35
SM
Details
Card read/write error. Software or
card defective.
Download dysfunction 1
Print download is not possible.
Cannot download to HDD because
HDD not installed or defective.
Download dysfunction 2
Download continuity error with more
than one card. The second or later
card is not compatible.
Download dysfunction 3
Download interrupted because card
is not correct, or power failure
interrupted download.
Download dysfunction 4
Card version error. Attempted to
download program using a card with
the wrong version number.
Download dysfunction 5
Specification error. DOM card set in
EXP machine, or vice versa.
Download dysfunction 6
Wrong model. The inserted card is
for another model.
6-9
Program Download
Recovery
off/on and re-try
Replace the card
Replace the
controller board
HDD defective
HDD harness
disconnected,
defective
Set the correct
cards in the
correct order
Use the correct
card
If power failure
caused the failure,
remove the card
and insert another.
Use the correct
card
Use the correct
card
Use the correct
card
D062/D063/D065/D066