Service Program Mode Tables
-002
TD Sensor Initial Setting Developer Lot Number Input
2803
Charge Cleaner Start Time
Press EXECUTE button to clean the charge corona wire manually.
001
When copy density across the paper is uneven, clean the wire with this mode.
2804
Charge Cleaner Operation Setting
001 Operation Mode
Determines whether the charge corona wire is cleaned at regular intervals.
[0 to 1/1]
0: No
1: Yes
The time interval between cleaning is set with SP2804-002.
002 Number of Sheets
Sets the interval (number of sheets printed) between charge corona wire
cleanings.
[100 to 10,000/5000/100]
Exposure Gamma Table DFU
2813
Is the gamma table is used when the printing test pattern is done with SP2902
003.
[0 to 1/1]
0: Gamma table used in the printing test pattern.
1: Forces test pattern output with SP2902 003. The write exposure gamma table
is not applied. Current image mode selection or other settings are ignored.
2901
Humidity Control
0: OFF 1:ON
001
[0 or 1/ 0 / -]