Ricoh D065 Service Manual page 633

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Service Program Mode Tables
001 Paper Supply Alarm
Switches the control call on/off for the paper supply. DFU
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified number transfer sheets for each
paper size (A3, A4, B4, B5, DLT, LG, LT, HLT)
002 Staple Supply Alarm
Switches the control call on/off for the stapler installed in the finisher. DFU
0: Off, 1: On
0: No alarm
1: Alarm goes off for every 1K of staples used.
003 Toner Supply Alarm
Switches the control call on/off for the toner end. DFU
0: Off, 1: On
If you select "1" the alarm will sound when the copier detects toner end.
080 Toner Call Timing
Changes the timing of the "Toner Supply Call" via the NRS, when the following
conditions occur.
0: Toner is replaced (default)
1: Toner near end or End
128 Interval: Others
132 Interval: A3
133 Interval: A4
134 Interval: A5
141 Interval: B4
142 Interval: B5
160 Interval: DLT
164 Interval: LG
D062/D063/D065/D066
The "Paper Supply Call Level: nn" SPs specify the
paper control call interval for the referenced paper
sizes.
[00250 to 10000 / 1000 / 1 Step]