does not operate when copying with OHP, index sheets, or thick paper.
If blurring occurs in images at the leading edges of copies, switch
SP2602-001 off (set to "0").
ON/OFF Setting
001
(1st Side)
OFF Timing (1st
002
Side)
ON/OFF Setting
003
(2nd Side)
OFF Timing (2nd
004
Side)
2801*
TD Sensor Initial Setting
Press the EXECUTE button to do the TD sensor initial setting. This SP mode
controls the voltage applied to the TD sensor to make the TD sensor output
-001
about 3.0 V.
When SP2967 is on, the TD sensor output is set to about 2.5 V.
Note: Execute this SP only after replacing the TD sensor or developer.
SM Appendix
Turns the PTL lamp on/off during transfer to the front side of
the paper at normal speed. This setting is always off when
thick paper or OHPs are fed.
[0 to 1/1]
0: Off
1: On
The timing can be adjusted with SP2602-002.
Adjusts the length of the space from the leading edge where
PTL quenching is applied to the front side at normal speed.
For example, if you select +3, then quenching will be done 3
mm from the leading edge on the front side.
[-10 to 20/3/1 mm]
Turns the PTL lamp on/off during transfer to the front side of
the paper at normal speed.
[0 to 1/1]
0: Off
1: On
Adjusts the length of the space from the leading edge where
PTL quenching is applied to the back side at normal speed.
For example, if you select +3, then quenching will be done 3
mm from the leading edge on the back side.
[-10 to 20/3/1 mm]