006 ID Sensor Pattern Potential
Displays Vid, the latest drum surface voltage measured on the ID sensor
pattern.
[0 to 0xFFFF/0/0]
007 Vql
Displays the drum potential after quenching.
[0 to 0xFFFF/0/0]
008 Vl
Shows the standard electrical potential of white areas on the drum after
exposure.
[-32767 to 32768/0/0]
3903*
Drum Rotation Time Extension Mode
001 (0:OFF/1:ON)
Turns on the drum rotation mode. This increases the time that the drum turns
freely after the machine is turned on. After this function is turned on with this SP,
it will be enabled only when SP3904 001 is set to "2". If SP3904 001 is set to "0"
or "1", the extra drum rotation mode will not be enabled.
[0 to 1/1]
0: Extra drum rotation mode is off.
1: After auto process control, the drum continues to turn until the fusing unit gets
to its operation temperature. Use this setting to decrease out-of-focus copy
images when the machine is used immediately after power-on.
002 Drum Rotation Time
Sets the amount of time the drum turns in the drum rotation mode before the first
copy after the machine is turned on. SP3903-001 must be on or this setting has
no effect.
[120 to 600/240/1]