Fusing Temperature Display
001 Center Temperature
002 End Temperature
Pressure Roller
003
Temperature
1107
Start Fusing Adjustment
This SP allows you to set when to start the fusing temperature adjustment for
the center and end heating lamps.
001 Center Lamp Temperature
002 End Lamp Temperature
003 Center Lamp Actual Time
004 End Lamp Actual Time
SM Appendix
D066: [150 to 200/185/1degree C]
Fusing temperature at center of hot roller when
printing on normal paper:
D062/D063/D065: [150 to 205/190/1 degree C]
D066: [150 to 200/185/1 degree C]
Fusing temperature at center of hot roller when
printing on thick paper:
D062/D063/D065: [150 to 205/190/1 degree C]
D066: [150 to 200/195/1 degree C]
Shows the temperature of the hot roller detected by
the thermistor at the center of the hot roller.
Shows the temperature of the hot roller detected by
the thermistors at the ends of the hot roller.
Shows the temperature of the hot roller detected by
the thermistors at the pressure roller.
D062/D063/D065: [150 to 205/205/1 deg C]
D066: [150 to 190/190/1 deg C]
D062/D063/D065: [0 to 120/60/1 sec.]
D066: [0 to 60/10/1 sec.]
D062/D063/D065: [0 to 120/55/1 sec]
*For Only TWN [0 to 120/60/1 sec]
D066: [0 to 60/10/1 sec]