Ricoh D065 Service Manual page 627

Hide thumbs Also See for D065:
Table of Contents

Advertisement

Service Program Mode Tables
002 Lockout Threshold
Sets a limit on the frequency of lockouts for account lockouts.
[1 to 10 / 5 / 1/step]
003 Cancellation On/Off
Determines whether the system waits the prescribed time for input of a correct
user ID and password after an account lockout has occurred.
[0 or 1 / 0 / -]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct user ID and password are
entered.
004 Cancellation Time
Determines the length of time that the system waits for correct input of the user
ID and password after a lockout has occurred. This setting is used only if
SP5413-3 is set to "1" (on).
[1 to 999 / 60 / 1 min./step]
005 Counter Clear Time
Not used.
5414
Access Mitigation
001 Mitigation On/Off
Switches on/off masking of continuously used IDs and passwords that are
identical.
[0 or 1 / 0 / -]
0: Off, 1: On
002 Mitigation Time
Sets the length of time for excluding continuous access for identical user IDs and
passwords.
[0 to 60 / 15 / 1 min./step]
D062/D063/D065/D066
4-94
SM Appendix

Advertisement

Table of Contents
loading