Configuring Features - GE NX-10 Installation Manual

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

The keypad beeps once to accept the change and returns to Outputs.
8.
Table 9. NX-320-I output events
#
Event
Alarms
17
Alarm Memory
Tests
3
Dyn Battery Test
Tampers
25
Fire LED
11
Smoke Det Reset
8
Over-current
9
Box Tamper
10
Siren Tamper
26
Fire Trouble
1
Mains Failure
2
Low Battery
Note:
Faults on outputs are restored after a valid PIN is entered at the keypad.

Configuring features

You can configure testing and reporting features for the NX-320-I power module. The following
example enables a battery test which lasts for 60 minutes and sends a report to the central station
when a low battery condition occurs.
1. Navigate with the
and press OK.
2. Scroll to Battery Test>Enabled and press OK.
3. The keypad beeps once to accept the change and returns to Battery Test.
4. Scroll to Battery Test Time and press OK.
5. Select 60 min. and press OK. The keypad beeps once to confirm the change and returns to
Battery Test Time.
7. Scroll to Reports>Low Battery>Yes and press OK.
8. The keypad beeps once to accept the change and returns to Low Battery.
#
Event
Arm/disarm
21
Armed
22
Disarmed
23
Ready to Arm
18
Entry
19
Exit
20
Entry or Exit
24
Not Ready to Arm
Sirens
12
Burglary Siren
13
Fire Siren
14
Any Siren
15
Fire Sir Steady
16
Any Sir Temporal
keys to NX-320-I Power Modules>Power Module 84>Feature Select
NX-10 Expander Installation Guide
#
Event
Misc
32
Code Entry
7
Program Mode
0
Always On
Keypads
29
Keypad Fire
30
Keypad Medical
31
Keypad Panic
28
Keypad Beeping
27
Chime
Communications
4
Listen-in
5
Line Seizure
6
Phone Line Fault
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents