Note: The zone/user for the corresponding output must be "0" to use this location.
LOCATION 89 - AUTHORIZING USERS 211 - 220 TO TRIGGER OUTPUTS 1 - 8 (10 segments,
feature selection data)
When activating outputs with a user code, location 89 can be used to restrict certain codes from
activating certain outputs. Location 89 contains 10 segments. Segment 1 corresponds to user 211,
segment 10 corresponds to user 220. Refer to location 68 chart.
Note: The zone/user for the corresponding output must be "0" to use this location.
LOCATION 90 - AUTHORIZING USERS 221 - 230 TO TRIGGER OUTPUTS 1 - 8 (10 segments,
feature selection data)
When activating outputs with a user code, location 90 can be used to restrict certain codes from
activating certain outputs. Location 90 contains 10 segments. Segment 1 corresponds to user 221,
segment 10 corresponds to user 230. Refer to location 68 chart.
Note: The zone/user for the corresponding output must be "0" to use this location.
LOCATION 91 - AUTHORIZING USERS 231 - 240 TO TRIGGER OUTPUTS 1 - 8 (10 segments,
feature selection data)
When activating outputs with a user code, location 91 can be used to restrict certain codes from
activating certain outputs. Location 91 contains 10 segments. Segment 1 corresponds to user 231,
segment 10 corresponds to user 240. Refer to location 68 chart.
Note: The zone/user for the corresponding output must be "0" to use this location.

NX-507E/NX-508E Programming worksheets

(Defaults are printed in bold italic text)
LOC
0
OUTPUT 1: EVENT, ZONE, TIME
1
OUTPUT 1: SPECIAL FEATURES & PARTITIONS
1
ON: if timed in minutes. OFF: if timed is seconds
2
ON: If latched until code is entered. OFF: for timed
3
ON: If output should stop timing when a code is entered. OFF: timed
4
ON: If output should only trigger during a closed schedule
5
ON: If output should only trigger during an open schedule
6
ON: If the output should be inverted
7
ON: If a trigger should be logged in the event buffer
8
Reserved
DESCRIPTION
Segment 1 (Circle Numbers To Program)
Segment 2 (Circle Numbers To Program)
NX-10 Expander Installation Guide
DEFAULT
PROGRAMMING DATA
43 1 10
95