Segment 6 - Time remaining tone indicator "A" (default = 20 seconds)
Location 3, segment 6 is used to determine how many seconds will remain when the NX-534E sends
tone indicator "A" to the central station. This time is used to alert the central station that the two-way
session will be terminated if there is no further activity from the central station. Valid entries are 1 to
255 seconds.
Segment 7 - Time remaining tone indicator "B" (default = 10 seconds)
Location 3, segment 7 is used to determine how many seconds will remain when the NX-534E sends
tone indicator "B" to the central station. This time is used to alert the central station that the two-way
session will be terminated if there is no further activity from the central station. Valid entries are 1 to
255 seconds.
Segment 8 - Anti-lock-up tone time (default = 0 seconds)
Location 3, segment 8 is used to determine at what interval the anti-lock-up tone will be heard at the
central station. This tone is used to prevent noise in an exceptionally loud environment from
interfering with central station's control of the two-way session. The possible values are 0-255
seconds. If a 0 is programmed (default), it is disabled and no tone will be generated.
LOCATION 4 - VOLUME / RING CONTROL (4 segments, numerical data)
Segment 1 - Low gain listen-in mode microphone volume (default = 5)
Location 4, segment 1 controls the volume of the microphones when the central station selects low-
gain listen-in mode. The possible value for this location is 0 to 9 (maximum volume is 9 and
minimum is 0).
Segment 2 - High gain listen-in mode microphone volume (default = 9)
Location 4, segment 2 controls the volume of the microphones when the central station selects high-
gain listen-in mode. The possible value for this location is 0 to 9 (maximum volume is 9, minimum
volume is 0).
Segment 3 - Speaker volume (default = 9)
Location 4, segment 3 governs the volume of the speaker when talk is selected by central station. The
possible value for location 4 is 0 to 9 (maximum volume is 9, minimum volume is 0).
Segment 4 - Number of rings to answer for call-in feature (default = 0)
Location 4, segment 4 determines the number of rings the NX-534E must see before answering the
call while in the call-in mode (refer to location 0, segment 6). Valid entries are 0 - 9. If a 0 is
programmed, it will pick up immediately. A master code is required within 20 seconds of the line
pickup or the line will be disconnected.
LOCATION 5 – PROGRAMMING X-10 ADDRESS FOR OUTPUT 1 (2 segments, numerical data)
IMPORTANT NOTICE: An X-10 interface module, i.e. NX-507E/NX-508E, must be present for this feature to work
properly.