LOCATION 2 - PROGRAMMING THE EVENT AND TIME FOR OUTPUT B (2 segments, numerical
data)
Segment 1 - event
Is used to program the particular event that will trigger the output. See chart on page 8 for the
specific events that can be selected.
Segment 2 - time
Is used to select the amount of time an output will remain activated when an output triggers. If this
location is programmed as a zero, the output will follow the particular event.
LOCATION 3 - PROGRAMMING SPECIAL FUNCTIONS AND PARTITIONS FOR OUTPUT B (2
segments, feature selection data)
Segment 1 - selects the following special conditions
Option
Function
1
ON
If output should time in minutes
OFF
If output times in seconds
2
ON
Output "Latch": should latch until a code is entered
OFF
Output is timed
3
ON
Timed or output should be reset if a code is entered while it is being timed
OFF
Stays timed (not reset) after code is entered
4
ON
For inverted output
5
ON
Disables output during listen-in (only events 12-16)
6
Reserved
7
Reserved
8
Reserved
Segment 2 - selects the following partitions
Option
Function
1
ON
If the event should activate when it occurs in partition 1
2
ON
If the event should activate when it occurs in partition 2
3
ON
If the event should activate when it occurs in partition 3
4
ON
If the event should activate when it occurs in partition 4
LOCATION 4 - PROGRAMMING THE EVENT AND TIME FOR OUTPUT C (2 segments, numerical
data)
Segment 1 - event
Is used to program the particular event that will trigger the output. See chart on page 8 for the
specific events that can be selected.
Segment 2 - time