Configuring An Output; Configuring Users - GE NX-10 Installation Manual

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

Configuring an output

You can specify events, users and partitions that can activate a particular output. The output can be
controlled using a schedule or by an X-10 device. If an output is controlled by a schedule, it can be
activated during the times specified in the schedule only. If it is controlled by an X-10 device, it can
be activated during the time the X-10 device is switched on or off. The following example configures
output 1 on output expander 24 to be activated by a box tamper event. This output is controlled by
schedule 1.
Navigate with the
1.
Scroll to Output 1>Event>Tamper/Trouble>Box Tamper and press OK.
2.
The keypad beeps once to accept the change and returns to Tamper/Trouble.
3.
Scroll to Schedules and press OK.
4.
Press the relevant keys to select schedule only and press OK.
5.
The keypad beeps once to accept the change and returns to Schedules.
6.

Configuring users

You can specify the user code that triggers the selected output. The following example sets user code
1 to activate outputs on output expander 24.
Navigate with the
1.
press OK.
Scroll to Event>Miscellaneous>Code Entry and press OK.
2.
The keypad beeps once to accept the change and returns to Miscellaneous.
3.
Scroll to Zone/User>(User) 1 and press OK.
4.
The keypad beeps once to accept the change and returns to Zone/User.
5.
Navigate with the
6.
Press the relevant keys to select the outputs that the user code can activate and press OK.
7.
The keypad beeps once to accept the change and returns to Outputs.
8.
keys to NX-507/508E>Output Exp 24>Outputs and press OK.
keys to NX-507/508E>Output Exp 24>Outputs>Output 1 and
keys to Users>User 1>Outputs and press OK.
NX-10 Expander Installation Guide
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents