Control Levels - GE NX-10 Installation Manual

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

The line disconnects (goes off the hook).
3.
The NX-534E listen-in module starts the call back window timer. If the time runs out
4.
before the number of rings has been reached, the system returns to stand-by mode and
waits for a new trip.
The NX-534E listen-in module waits to receive the call back, up to the selected number
5.
of minutes programmed in for the first ring.
The NX-534E listen-in module sends a continuous indicator tone to the central station
6.
until the access code is received or the maximum number of attempts is exhausted. When
a code is received, the indicator tone is silenced.
The NX-534E listen-in module waits for the access code to match. The reset [#] key may
7.
be used during PIN entry to clear the PIN buffer. If the access code does not match after a
set number of attempts, the system returns to stand-by mode and waits for a new trip. If
the code is validated, the system silences the siren and starts a two-way session.

Control levels

Levels of the modes may be changed at any time by pressing * followed by the level number you
wish to access on a touch-tone telephone. If no key is pressed for 3 seconds on the telephone, then the
buffer is automatically cleared. Press * on the telephone twice to return to the beginning.
•If a new alarm in the same partition is activated during a two-way session, the session timer can be
extended by pressing a key before the session times out.
•If a new alarm in a different partition is activated during a two-way session, the timer is reduced to
20 seconds, and cannot be extended.
Note:
Levels 1, 2 and 4 are not supported. Attempts to access these levels will revert to Level 0.
Table 13. NX-534E control levels
0
1
Level
3
0
2, 4, 5, 7, 8, 9
6
88
99
Level
3
0
1
2
Returns to the initial session settings when it is tripped. This includes the
microphone selection and audio mode.
High gain talk to the premises and extends the session time.
High gain listen-in from the premises and extends the session time.
Extends the session time.
Low gain listen-in from the premises and extends the session time.
Terminates the session and starts the call back mode.
Terminates the session and returns to the stand-by mode and waits for a new trip.
Returns to the initial session settings when it was tripped. This includes the
microphone selection and audio mode.
Turns microphone 1 on, microphone 2 off, and extends the session time.
Turns microphone 2 on, microphone 1 off, and extends the session time.
Basic control level
Microphone control (zoning)