default setting is <YES>.
-Network Restart
Network restart is required after changing network settings. Select
<YES>
5.1.6.2 Trigger Port
To avoid the default service port (port 80) to be blocked, the item enables
user to change port 80 into another port.
To change the trigger port, move the cursor over <Trigger Port> and
press ENTER, then adjust the setting by UP / DOWN buttons.
5.1.7 RS485 Setup
This menu allows setting up the parameters of the unit's RS-485
communications port. From the Main menu, select <RS485 Setup> and
press ENTER. The following menu is displayed.
1. Unit ID
2. Baud Rate
3. Bits
4. Stop
5. Parity
5.1.7.1 Unit ID
This item is used to change the RS-485 ID address of the unit. The ID is in
the
5.1.7.2 Baud Rate
to
restart
RS485 Setup
range
of
<1>
the
224
9600
8
1
None
to
<255>.
The
network
device.
default
is
<224>.