Printer Options (continued)
Menu Item
RETRY ATTEMPTS
3
(0 - 9)
AUTO DETECT TAG
SET DEFAULTS
YES
NO
GPIO PORT
GPIO DEVICE
APPLICATOR
APPLICATOR2
BARCODE VERIFIER
DISABLED
34
Sets the number of retry attempts, where:
Is the retry count before a fault is declared.
Allows the printer to establish the tag to transducer
distance setting. CALIBRATING RFID will appear as
media is scanned for the tag location. Upon completion,
the media will be retracted to the TOF position with the
positioning results (along with a brief SUCCESS or
FAILURE message).
Allows the RFID default values to be restored, where:
Restores the default settings.
Exits the menu item without changing the current
settings.
Controls the GPIO operation, where:
Sets the GPIO option to work with a specific device
type, where:
Enables parameters for related label applicator
functions:
Completion upon last SOP, de-asserts Data Ready
•
(DRDY);
FEED allowed at any time; and,
•
DRDY upon PAUSE.
•
Enables parameters for alternate label applicator
functions:
Completion upon 1 msec. overlap of Data Ready
•
(DRDY) and End of Print (EOP);
DRDY signal end inhibits FEED; and,
•
De-asserts DRDY upon PAUSE or FAULT.
•
Enables the GPIO Port to work with a bar code verifier.
Disables the option.
Details