Advanced Entry Calibration (continued)
Step
Action
Press the
Place the label under the
7
Sensor Eye Mark, and then
lower the printhead
assembly.
Use the
to the 00 GAIN setting and
then press the
8
Record the sensor reading
as a Label Value in a table
similar to the one shown
below.
Step
Action
Press the
increment the Gain Number
then press the
and record the resulting
Label Value.
9
Repeat this step for each of
the remaining Gain
Numbers (01-31).
66
Displayed Message
GAIN TRAN
Key.
*00
Or, for reflective media:
GAIN REFL
*00
GAIN TRAN
Key to scroll
*00
Key.
Or, for reflective media:
GAIN REFL
*00
Sampling Table
Gain
Label
Number
Value
00
255
01
02
...
31
Displayed Message
Key to
GAIN TRAN
*31
Key
Or, for reflective media:
GAIN REFL
*31
See Section 3.3 for
<yyy>
sensor positioning
<0 - 31>
details.
!
!
If using preprinted
media, ensure the label
!
area under the Sensor
<yyy>
Eye Mark is free of text,
<0 - 31>!
graphics, or borders.
Selection is denoted by
an asterisk (*).
<yyy>
<0 - 31>
The sensor reading
!
equals the "yyy" value.
!
Note: Never position
the sensor over a
<yyy>
perforation when
<0 - 31>!
sampling.
TOF
Difference
Value
Value
<yyy>
<0 - 31>
!
!
<yyy>
<0 - 31>
!
Comment
Comment
I-Class