Removing Used Ribbon
When the Ribbon Roll is depleted, pull the empty core from the Ribbon Supply Hub. Grasp
the used roll on Ribbon Take-Up Hub then pull and squeeze to remove the spent ribbon.
(To remove partially depleted rolls, cut the ribbon then remove the roll and discard any
used ribbon as described above.)

3.5 Quick Calibration

The printer is calibrated to sense a wide range of media. Calibration fine-tunes these
settings for your die-cut, notched, or reflective application. (Not required for continuous
media.)
Perform this calibration during initial setup or after changing your media type:
Ensure that media is loaded and that the Media Sensor is adjusted. Then, with the
printer idle, press and hold the FEED Key. Allow at least one complete label to advance
then release the key.
Upon successful completion, CALIBRATION COMPLETED and then READY will be
displayed.
Notes:
If UNCALIBRATED is displayed, see Section 5.2.
If the printer displays CANNOT CALIBRATE or stops feeding mid-label, press and hold
the FEED Key until two (or more) labels are advanced before releasing the key. If this
method also fails, see Section 5.2.
WARNING LOW BACKING may appear if using notched media, or media with a
transparent liner; however, calibration was successful.
Media containing large gaps may require a change in the PAPER OUT DISTANCE; see
Section 4.2.2.
I-Class
17