Printer Options (continued)
Menu Item
BARCODE COUNT
00
(0 - 99)
MIN READABLE HEIGHT
DISABLED
1/16 – ½ in
(1.5–12.5mm)
REDUNDANCY LEVEL
READ BARCODE 3X
AUTO
IGNORE NO DATA
DISABLED
ENABLED
SET DEFAULTS
SET FACTORY DEFAULT?
CANCEL KEY = YES
30
Specifies a number of bar codes per label and
generates a fault when the number present is incorrect,
where:
Sets the number of bar codes to count, where 00 (Auto
Mode) allows a variable number.
Note: If bar codes are bitmaps, enter the minimum
number to be read on each label (check your
software application if questioning the bar
code generation method).
Ensures bar code integrity by setting a minimum
distance for identical decodes, where:
Uses REDUNDANCY LEVEL to ensure bar code integrity.
Sets a read distance requirement to pass the bar code
(e.g., ¼ requires .25 inches to be readable).
Note: This distance should not exceed 50% of the
measured bar code height.
Ensures bar code integrity by specifying a consecutive
number of identical decodes, where:
Sets a valid read count requirement (1X – 6X) to pass
the bar code (e.g., 3X must return three identical
decodes).
Note: High redundancy rates and fast print speeds
may cause erroneous read failures when
scanning small or multiple bar codes.
Uses MIN READABLE HEIGHT to ensure bar code
integrity.
Allows an override of data verification, where:
Checks for correct bar code data in the bar code(s).
Ignores the data present in the bar code(s).
Restores the scanner settings to the default values,
where:
Restores the defaults, or press the ESC Key to keep the
current configuration.