4.2.7 Diagnostics

The Diagnostics menu contains testing functions:
Menu Item
HEX DUMP MODE
DISABLED
ENABLED
OPTIONS TESTING
TEST PRESENT SENSOR
PERFORM TEST
1 TIME
TEST CUTTER
PERFORM TEST
1 TIME
TEST GPIO
MONITOR GPIO INPUT
MONITOR GPIO OUTPUT
I-Class
Allows raw code received from the host to print, where:
Executes commands and prints label formats normally.
Prints received data without processing; see Section
6.2.
Allows testing of printer options, where:
Tests the Present Sensor (and Peel & Present
Mechanism) on demand function, where:
Selects the number of LABEL PRESENTED tests (1, 10,
or 100) to perform, and then displays the results.
Tests the Cutter, where:
Selects the number of cuts (1, 10, or 100) to perform,
and then displays the results.
Tests the General Purpose Input Output interface,
where:
Displays the logic values for Start of Print (SOP), Feed,
Pause, and Reprint (REPRT) signal inputs. (The values
given below are examples only.)
SOP
FEED
0
0
Note: Unconnected lines may assume a zero or one.
Allows toggling and displays the logic values for End of
Print (EP), Ribbon Low (RL), Service Required (SR),
Media Out (MO), Ribbon Out (RO), Data Ready (DR),
and Output Fault (OF) signal outputs. (The values given
below are examples only.)
EP
RL
SR
1
1
0
Note: To change an output signal, cursor over the
displayed state to select and then toggle it,
except Data Ready which cannot be toggled.
Details
PAUSE
0
MO
RO
DR
1
1
0
REPRT
0
OF
0