Fault Messages (continued)
Displayed Message
OUT OF STOCK
POSITION FAULT
PRESENT SENSOR FAULT
PRINT ENGINE FAULT
RAM FAULT
92
Fault Messages
Description
The printer cannot detect
media.
One of the following has
occurred:
An update was made
•
to the application
version;
The printer was
•
powered-off or reset
during a ribbon, out of
stock or TOF fault; or,
The printer was unable
•
to complete the
calibration.
The printer cannot detect
the Present Sensor.
The printer has detected a
problem within the print
logic.
The system has detected a
memory failure.
Action(s)
Try the following procedures:
Load media. Ensure that the
•
labels are passing through the
Media Sensor and, if
necessary, readjust the Media
Sensor over the TOF mark;
see Section 3.3. Also, if using
media with large gaps, adjust
the PAPER OUT DISTANCE
(see Section 4.2.2); or,
Calibrate the printer; see
•
Section 5.2.
Try one of the following
procedures:
Press the FEED Key then clear
•
any related fault condition; or,
Calibrate the printer; see
•
Section 5.2.
Ensure that the option is
installed properly. Try cycling the
power OFF and ON. If the fault
does not clear, call for service.
Try cycling the power OFF and
ON. If the fault does not clear,
call for service.
Try cycling the power OFF and
ON. If the fault does not clear,
call for service.