Fault Messages (continued)
Displayed Message
TOP OF FORM FAULT
VERIFIER FAULT
I-Class
Fault Messages
Description
The printer could not find
the TOF within the
maximum label length
setting, or TOF occurred in
an unexpected place.
Note: When using
reflective media, this fault
is given for an Out of Stock
condition.
The Verifier could not pass
a bar code.
Note: This is normal
when a bar code is
unreadable.
Action(s)
If media is moving:
1) Press the FEED Key. It may be
necessary to re-calibrate the
printer; see Section 5.2.
2) The Media Sensor may be out
of position. Readjust it; see
Section 3.3.
3) The media may not be
properly loaded. Reload
media, ensuring that the
Media Guide is properly
positioned; see Section 3.2.
4) The Leveling Cam may be
improperly adjusted; see
Section 5.4.1.
5) The label may be longer than
the value entered. Check the
Media Settings / Maximum
Label Length; see Section
4.2.2.
6) The Media Sensor may be
obstructed. Check and
carefully remove any
obstruction (labels, paper
dust, adhesive, etc).
If media is not moving:
The printhead assembly may not
be locked.
Simultaneously press the ENTER
and F1 Keys on the Verifier to
clear the fault. If the fault
persists, consult the option's
instructions.