Programmed Scan Operation; F Scan Operation - Icom IC-7600 Instruction Manual

Hf/50 mhz
Hide thumbs Also See for IC-7600:
Table of Contents

Advertisement

7
SCANS

■ Programmed scan operation

q Push [EXIT/SET] several tmes to close a mult-
functon screen, f necessary.
w Select VFO mode.
e Select the desred operatng mode.
• The operatng mode can also be changed whle scan-
nng.
r Push [SCAN] (F-5) to select the scan screen.
t Set [RF/SQL] open or closed.
• See p. 105 for squelch condton.
• If the [RF/SQL] control functon s set as "AUTO," the
squelch s always open n SSB, CW, RTTY and PSK
modes. (pgs. 2, 33, 128)
y Push [PROG] (F-1) to start the programmed scan.
• "
scannng.
u When the scan detects a sgnal, scan stops,
pauses or gnores t dependng on the resume set-
tng and the squelch status.
i To cancel the scan, push [PROG] (F-1).
• Rotatng the man dal also cancels the scan.
o Push and hold [RECALL] (F-5) for 1 sec. to recall
the frequency that s set before startng the scan, f
desred.
If the same frequences are programmed nto the
scan edge memory channel P1 and P2, pro-
grammed scan wll not start.
■ ∂F scan operation
q Push [EXIT/SET] several tmes to close a mult-
functon screen, f necessary.
w Select VFO mode or a memory channel.
e Select the desred operatng mode.
• The operatng mode can also be changed whle scan-
nng.
r Push [SCAN] (F-5) to select the scan screen.
t Set [RF/SQL] open or closed.
• See p. 105 for squelch condton.
• If the [RF/SQL] control functon s set as "AUTO," the
squelch s always open n SSB, CW, RTTY and PSK
modes. (pgs. 2, 33, 128)
y Set the ∂F span by pushng [∂F SPAN] (F-4).
• ±5 kHz, ±10 kHz, ±20 kHz, ±50 kHz, ±100 kHz,
±500 kHz and ±1000 kHz are selectable.
u Rotate the man dal to set a center frequency of
the ∂F span.
i Push [∂F] (F-2) to start the ∂F scan.
• "
" and decmal ponts blnk whle scannng.
o When the scan detects a sgnal, the scan stops,
pauses or gnores t dependng on the resume set-
tng and the squelch status.
!0 To cancel the scan, push [∂F] (F-2).
• Rotatng the man dal also cancels the scan.
!1 Push and hold [RECALL] (F-5) for 1 sec. to recall
the frequency that was set before startng the scan.
107
" and decmal ponts blnk whle
[RF/SQL]
F-1
F-5
PROG
SCAN
RECALL
SCAN
F-5
[RF/SQL]
F-2
F-4
∂F
∂F SPAN
Main dial
EXIT/SET
/
RECALL
EXIT/SET